a paper path problem, etc.
Code |
Description |
A1-1 to A1-32 |
All indicate a paper path problem, etc. in the ADF |
A2 |
ADF exit problems |
A3 |
Irregular size documents |
A5 |
ADF interlock |
A6 |
ADF single sheet document reset |
A7 |
Platen interlock |
A8 |
ADF exit interlock |
C1 |
Tray 1 jam |
C2 |
Tray 2 jam |
C3 |
Tray 3 jam |
C6-1, C6-2 |
Jams related to duplex |
C6-3 |
Registration sensor, re tray 1 |
C7-1, C7-2 |
HCF feed problems |
C7-3 |
Tray 1 feed problem |
C8 |
Paper stays in tray or duplex or HCF |
C9 |
Bypass feed problem |
E1-10 to E1-25 |
Internal jam |
E1-6 |
Paper on registration sensor |
E2 |
Reset signal happened. Might read E-2 something else |
E3-30 to E4-14 |
Exit jam |
E3-6 |
Exit jam |
E4-10 to E4-14 |
Inverter sensor not actuated |
E4-15 |
Inverter sensor |
E4-40 to E4-45 |
Duplex entry sensor |
E4-6 |
Inverter sensor |
E5 |
Front door interlock |
E6-1 |
Tray 1 interlock |
E6-2 |
2 tray or duplex interlock |
E6-3 |
HCF interlock |
E7-2, E7-3 |
Duplex interlock |
E8-6 to E8-15 |
Duplex entry sensor |
F1-1 |
Sorter entry sensor |
F1-6 |
Sorter exit sensor |
F3 |
Paper size not available for sort/stack |
F5 |
Sorter interlock |
J1 |
Add toner |
J3 |
Replace copy cartridge |
J7 |
Replace copy cartridge |
J8-1 |
Wrong copy cartridge installed |
J8-2 |
Copy cartridge EEPROM |
L6 |
Auditron or other counter problem |
L8 |
Platen glass temperature is too high |
L9 |
Communication problem between interimage erase/edge lamps and main board |
U1-1 |
Main motor drive problem |
U2-1 to U2-4 |
Scan home sensor |
U3-1 |
Lens sensor |
U4-1 |
Open fuser thermistor |
U4-2 |
Fuser did not warm up properly |
U4-3 |
Fuser temperature too high |
U4-4 |
Fuser problem. Staying on too long |
U4-6 |
High fuser temperature |
U5-1 |
Sorter bin home switch not activated |
U5-2 |
Sorter bin home switch stayed actuated |
U5-3, U5-4 |
Sorter bin home switch |
U6-1 |
ROM problem |
U6-2 |
RAM problem |
U6-3 |
Low battery |
U6-4 |
Incorrect value in NVM. Reinitialize main board with code 20-96 |
U8-1 to U8-6 |
Problem with exposure lamp, lamp sensor, lamp board |