If lit steadily, open door
Код ошибки |
Описание |
C2 |
Transfer corona problem |
CH |
If lit steadily, open door or other interlock. If flashing, developer unit not installed or not connected properly |
H2 |
Fuser thermistor |
H3 |
Fuser overheat. Triac pinched wire |
H4 |
Low fuser temperature. Lamp, thermal fuse, thermistor, connection |
L1 |
Scan problem. Did not leave home position |
L2 |
Scan left home, but did not complete scan |
L3 |
No return scan |
L4 |
Drive problem |
L5 |
Lens problem |
L9 |
Sorter index. If 0 is flashing, sorter index home sensor did not actuate. If 1 is flashing, sorter bottom actuator remained actuated |
U1 |
Battery. Replace battery (might have 2) and do simulation 13 to reset |
U2 |
Communication problem within boards. To reset, jumper test points W2 & U2 |