DV unit not installed, not
Код ошибки |
Описание |
CH |
Flashing: DV unit not installed, not connected properly |
CH |
Lit steadily: Sorter not installed or not turned on |
EE-EL |
During developer calibration, problem of some kind. Over toned |
EE-EU |
During developer calibration, problem of some kind. Under toned |
F1-00 |
Communication error between main board and sorter |
F1-02 |
Transport motor drive |
F1-04 |
Bin sensor problem. Upper or lower limit sensor problem |
F1-05 |
Sorter bin home sensor |
F1-06 |
Sorter bin motor drive |
F1-14 |
Take out sensor problem |
F2-31 |
Image density sensor problem |
F2-32 |
Drum mark sensor problem |
F2-35 |
Grid voltage correction will not work on the patch voltage is outside the expected range |
H2-00 |
Fuser thermistor open |
H3-00 |
Fuser temperature too high |
H4-00 |
Fuser temperature too low. Lamp, thermal switch, connections |
L1 |
Scan forward problem |
L3 |
Scan return problem |
L4 |
Drive problem; main motor, gear, sensor, bind |
L5 |
Lens problem |
L8-01 |
Zero cross (board problem) |
L8-03 |
Auto exposure sensor problem |
P |
Paper feed problem |
PC |
Card counter not installed |
U2-01 |
Memory loss |
U2-04 |
EEPROM error |
U5-00 |
Communication problem between main board and ADF |
U5-01 |
Registration sensor problem during adjustment, or adjustment value is not a valid number |
U5-02 |
Exit sensor adjustment problem; invalid adjustment value |
U5-11 |
Paper feed drive problem |
U5-12 |
Transport motor drive |