Дупликаторы Ricoh Priport VT-2250 (C215/C216)


Код ошибки

Неисправность

Возможные причины

E 01

Malfunction in cutter section: The cutter does not reach both right and left cutter position switches within 2 seconds



1) Drive wire cut

2) Drive section malfunction

3) No power supply

E 02

Malfunction in the paper table drive section: The lower limit sensor or the paper table height sensor status does not change even though the paper table UP or Down signal is applied

1) Drive worm gear broken

2) Mounting screw of the worm gear broken

3) No power supply

E 03

Malfunction in the program

1) Defective PROM

2) Defective control PCB

E 04

Temperature of the thermal head or the power supply unit is high: Temperature of the thermal head becomes greater than 57°C or the temperature of the power supply unit becomes greater than 85°C when the machine is in stand-by condition

1) Defective thermistor

2) Defective thermal head

3) Defective power supply unit

E 05

Malfunction in the image shifting section

1) Encoder connector of the image shifting sectiond is connected

2) Defective encoder

E 06

Mechanical lock: Drum rotation sensor detects that the drum rotation speed is abnormal

1) Mechanical lock

2) Main motor failure

E 07

Malfunction in the program (PROM). When using I/O check mode, "E 07" lights up if the ROM is defective. NOTE: When "E 03" is lit, access I/O check mode to check if the PROM is defective

Defective ROM

E 08

Thermal head drive signal (ENL) is defective

Defective image processing board