F.A.Q. по ремонту и обслуживанию копиров

       

An error is identified in




Код ошибки

Описание

E500

An error is identified in the communication between the sorter and copier

E510

The clock signal from the motor is absent for 250 ms or more

E513

The clock signal from the motor is absent for 250 ms or more

E530

The home position sensor (P17) fails to go OFF when an equivalent of 2560 pulses of the motor drive command has been generated

E531

The stapler unit swing sensor (MS9) fails to go ON within 500 ms after the motor drive command has been generated. MS9 fails to go back OFF within 1000 ms after it has gone ON

E540

The lead cam home position sensor (P12) fails to go OFF within 2000 ms after the motor drive command has been generated. P12 fails to go back ON within 2000 ms after it has gone OFF