The surface temperature of the
Код ошибки |
Описание |
E000 |
The surface temperature of the fixing assembly upper roller fails to rise by a specified value within 90 sec after power-on. The surface temperature of the fixing assembly upper roller fails to reach 150C within 8 min after power on. The surface temperature of the fixing assembly upper roller fails to reach 180C within 5 min after it has reached 150C. The surface temperature of the fixing assembly upper roller falls below 50C in standby |
E001 |
The surface temperature of the fixing assembly upper roller exceeds 250C |
E005 |
The cleaning belt inside the fixing assembly has been taken up more than a specified length |
E010 |
After generation of the main motor drive signal, two or more pulses are not received within 2 sec |
E020 |
The accumulative time during which the toner supply signal (TSP) has been generated by the developing assembly reaches 3 min |
E050 |
The holding tray home position signal (THP) is not generated within 4 sec while the holding tray motor drive signal (TMDP1,2) is being generated. The holding tray home position signal (THP) is generated 1 sec or more while the holding tray motor drive signal (TMDP1.2) is being generated |
E13 |
The error detection circuit on the waste toner feed motor driver PCB has detected on overcurrent |
E203 |
Input of two or more clock pulses is not received within 2 sec from the scanner motor drive signal is generated |
E210 |
The lens home position signal (LHP) is not generated within 4.8 sec after the power switch or door switch has gone ON. The lens home position signal (LHP) is generate 2 sec or more |
E240 |
An error has occurred in the microprocessor on the DC controller PCB |
E243 |
An error has occurred in the communication between the microprocessor of the DC controller PCB and the microprocessor in the control panel |
E710 |
An error has occurred in the communication between the DC controller PCB and the controller PCB of the option, and the DC controller has detected the error |