Low fuser temperature. Heat lamp,
Код ошибки |
Описание |
E000 |
Low fuser temperature. Heat lamp, thermoswitch, thermofuse, thermistor, SSR |
E001 |
High fuser temperature. Thermistor, SSR, pinched wire |
E002 |
Low fuser temperature. Same as E002 |
E003 |
Same as E000/E001 |
E010 |
Same as E002 |
E022 |
Motor drive problem |
E030 |
Counter |
E202 |
Scan motor, sensor |
E204 |
Scan motor, sensor |
E210 |
Lens motor, sensor |
E220 |
Exposure lamp |
E240 |
DC controller (main board) |
E401 |
Pickup drive problem (might be Doc. Feeder) |
E402 |
Document belt drive problem |
E404 |
Exit motor (document feeder) |
E411 |
Document sensor (document feeder) |
E500 |
Sorter/machine communication problem |
E510 |
Sorter drive problem |
E530 |
Sorter home sensor |
E531 |
Stapler unit swing sensor |
E540 |
Sorter cam sensor |
E541 |
Sorter cam sensor |
E710 |
DC controller (main board) |
E712 |
DC controller or document feeder board |